Refer to INSTALLATION section of this manual for the details. Fuses (3 pieces of 40A, 32VDC for 1KVA, 4 pieces of 40A, 32VDC for 2KVA and 6 pieces for 3KVA, 1 piece of 200A, 58VDC for 4KVA and 5KVA) are provided as over-current protection for the battery supply. Mecer Axpert MKS II 5KW 48V 4000W MPPT. Reference: MUS-SOL-I-AX-5NB. Condition: New product. Maximum PV Array Power. MPPT Range @ Operating Voltage. Mecer 1200va / 720w Inverter Price: R 2950 Simulated Sine Wave inverter. Overload and short circuit protection. Built in AVR for voltage regulation. LCD display for comprehensive information. Price includes Inverter with charger One-year warranty on the Inverter. Mecer 2400va / 1440w Inverter Price: R 3950.
Specifications for SOL-I-AX-5P
MECER HYBRID 5000VA / 5000W Hybrid Pure Sine Wave Inverter with Charger
MECER Axpert_MKS 5000VA / 5000W Hybrid Pure Sine Wave Inverter Power factor 1, MPPT Solar charge Controller 4000W 80Amp (solar panels not included), 220V AC Input, 48V DC Battery Input - requires deep cycle batteries (batteries not included), 80Amp AC Battery Charger, Overload and short circuit protection, Configurable AC/Solar Input Priority, 13.5Kg, Up to 9 of these unit can be connected in parallel. *Please take note of connection: Connect RED cable to (+) on battery and the (+) on the unit, and BLACK cable to (-) on battery and the (-) on the unit. Place cable lug directly onto the battery terminal first, follow up with the washer and then the lock washer, and then the nut. Do not put a washer between the battery terminal and cable. Connect the positive cable first. Follow instructions in manual.
Mecer
Overview:
Axpert MKS Off-Grid Inverter
Axpert MKS is equipped with MPPT solar charge controller to maximize and regulate DC power from the solar array for charging the battery bank. Transformerless design provides reliable power conversion in compact size. Besides, it's worry-free to start up motor-type loads such as refrigerators, motors, pumps, compressors and laser printers as well as electronic loads like TVs, Computers, power tool and battery chargers.
Features:
- Pure sine wave inverter
- Output power factor 1 (only 0.8 for 3KP/5KP Models)
- Built-in battery equalization function to extend battery life cycle
- Built-in MPPT solar charge controller
- Selectable input voltage range for home appliances and personal computers
- Selectable charging current based on applications
- Configurable AC/Solar input priority via LCD setting
- Compatible to mains voltage or generator power
- Battery equalization for optimized battery performance and lifecycle
- Parallel operation with up to 9 units only available for Axpert MKS 3KP/4KVA/5KVA*
Specifications:
© 2021 Respective owners and brand holders. This table has been carefully researched and generated by ComXpert International CC (//www.comx-computers.co.za), however, errors and omissions may occur. Only references to South Africa apply. All products are sourced in South Africa from the official suppliers and the warranty is that of the local supplier. E&OE. This table and our site's content may be used on condition that this notice and link remains intact and unaltered. | |
Specifications and features | |
Product Code | SOL-I-AX-5P |
Model | Axpert MKS 5K-48 |
RATED POWER | 5000VA/ 5000W |
Parallel Capability | Yes, 9 units |
INPUT | |
Voltage | 230 VAC |
Selectable Voltage Range | 170-280 VAC (For Personal Computers), 90-280 VAC (For Home Appliances) |
Frequency Range | 50 Hz/60 Hz (Auto sensing) |
OUTPUT | |
AC Voltage Regulation (Batt. Mode) | 230VAC ± 5% |
Surge Power | 10000VA |
Efficiency (Peak) | 93% |
Transfer Time | 10 ms (For Personal Computers), 20 ms (For Home Appliances) |
Waveform | Pure sine wave |
BATTERY & AC CHARGER | |
Battery Voltage | 48 VDC |
Floating Charge Voltage | 54 VDC Max: 58 VDC (Optional 64 VDC, please check with sales) |
Overcharge Protection | 60 VDC (Optional 66 VDC, please check with sales) |
SOLAR CHARGER & AC CHARGER | |
Maximum PV Array Power | 4000W |
MPPT Range @ Operating Voltage | 60VDC ~115VDC |
Maximum PV Array Open Circuit Voltage | 145VDC |
Maximum Solar Charge Current | 80A |
Maximum AC Charge Current | 60A |
Maximum Charge Current | 140A |
Maximum Efficiency | 98% |
Standby Power Consumption | 2 W |
PHYSICAL | |
Dimension, D x W x H (mm) | 100 x 272 x355 |
Net Weight (kgs) | 13.5 |
OPERATING ENVIRONMENT | |
Humidity | 5% to 95% Relative Humidity(Non-condensing) |
Operating Temperature | 0°C to 55°C |
Storage Temperature | -15°C to 60°C |
IVR-2400LBKS 24v inverter
Features
• Simulated sinewave inverter
• Wide input voltage range
• 12VDC or 24VDC available
• Overload and short circuit protection
• LCD display for comprehensive information
• Optional solar charger
5kva Inverter Diagram
MODEL | IVR-1200LBKS | IVR-2400LBKS |
CAPACITY | 1200VA/ 720W | 2400VA/ 1440W |
INPUT | ||
Voltage | 230 VAC | |
Acceptable Voltage Range | 90-280 VAC | |
Frequency | 50 Hz/60 Hz (Auto sensing) | |
OUTPUT | ||
AC Voltage Regulation (Batt. Mode) | ± 10% | |
Efficiency (Peak) | 82% | 85% |
Transfer Time | 20 ms typical | |
Waveform (Batt. Mode) | Simulated sine wave | |
BATTERY & AC CHARGER | ||
Battery Voltage | 12 VDC | 24 VDC |
Floating Charge Voltage | 13.7 VDC ±2% | 27.4 VDC ±2% |
Low Battery Alarm Voltage | 10.2Vdc ±2% | 20.4Vdc ±2% |
Shutdown Voltage | 9.9Vdc ±2% | 19.8Vdc ±2% |
Overcharge Protection | 15.0Vdc ±2% | 30.0Vdc ±2% |
Maximum Charge Current | 10 A or 20 A (Selectable) | |
SOLAR CHARGER (Optional) Solar Charge controller not included,will request to purchase separately | ||
Maximum PV Array Open Circuit Voltage | 40 VDC | 60 VDC |
Operating Voltage Range | 15~18 VDC | 30~32 VDC |
Maxmum Solar Charge Current | 50 A | |
PROTECTION | ||
Full Protection | Overload, short circuit and polarity reserve protection | |
PHYSICAL | ||
Dimension, D X W X H (mm) | 300 x 360 x 88 | |
Net Weight (kgs) | 4.6 | 4.8 |
OPERATING ENVIRONMENT | ||
Humidity | 0 to 90% Relative Humidity(Non-condensing) | |
Operating Temperature | 0℃ to 40℃ | |
Storage Temperature | -15℃ to 50℃ |